Medicraft Company aims to present its research and development studies in production of respiratory support and therapy devices. Medicraft devices have become followed and appraised devices over the world market since they meet all the expectations.

CPAP

Digital PID pressure controlled function 4-20 mbar pressure range - Recording sleep events with 4GB SD Card - 3 step flex - Smart 4 button system - Wide graphic LCD screen - Automatic accessory detection system - Ramp function - Mask test


AUTO CPAP

Three channel Autocpap algorithm (Apnea-Snore-Upper Respiratory Tract Resistance) Medicraft Autocpap function method Sensitive snore detection thanks to digital filter that is applied with high speed sampling Maximum, minimum and startup pressure setting


BiLEVEL S

6 steps trigger sensitivity 8 steps slope adjustment 3 step flex function 25 mbar Standard Features Digital PID pressure controlled function Function in four different modes: CPAP, AUTOCPAP and BILEVEL S


BiLEVEL AP

Medicraft AUTOBiLEVEL operation method: Independent modification of inspiration and expiration pressures by considering sleep events. Function in four different modes: CPAP, AUTOCPAP, BILEVEL S ans AUTOBiLEVEL which is special to Medicraft BiLEVEL AP. Three channel AUTOBiLEVEL algorithm: Apnea, Snoring, Upper Airway Resistance


BiLEVEL ST

35 mbar – Frequency, I / E ration and tidal volume monitoring on LCD T Mode assist function Standard Features Digital PID pressure controlled function Function in five different modes: CPAP, AUTOCPAP, BILEVEL S, BİLEVEL T and BILEVEL ST


BiLEVEL PV

PV (Pressure-Volume): It has the principle of volume targeted-pressure function. The tidal volume that you want to apply is set and the device adjusts necessary I-PAP pressure for the application of tidal volume which is aimed during inspiratory phase. It functions in 4-35 mbar pressure range with the target of 200-1500 ml tidal volume.


ASV

Medicraft ASV operation method Standard Features Digital PID pressure controlled function Function in 7 different modes: CPAP, AUTOCPAP, BILEVEL S, BÄ°LEVEL T, BILEVEL ST, BILEVEL PV ans ASV, 4-35 mbar Pressure Range 200-1500 ml target volume


HUMIDIFIER

Standart Features 5 stage humidity and temperature adjustment feature Security system which averts the flow of water and humidity into the device Elegant outlook which is suitable for the design of device Setting lines for the amount of water Automatic connection lock system Automatic detectio


ACCESSORIES

Carrying Bag - Power Supply - Mask (Nasal and Full Face) - SD Card - Internal Battery






© Teqnia For Enginerring And Development